사업부소개
Busduct System
High Power Busduct
주요 특징
  • 70,000 kilometers busway installed worldwide
  • IEC and UL full type tested for each and every rating
  • KEMA-KEUR, ASTA diamond, UL compliance
  • Seismic zone 4 compliance
  • Complete package solution
  • Made by Schneider Electric
  • Mylar insulation by DuPont
  • 99.9% copper purity
  • Bimetal technology
  • Steel/Aluminum housing
  • Continuous earth
주요 사양
Range I-Line II
Ratings Copper busway - 630A to 6300A, Aluminum busway - 800A to 5000A
Rated voltage 1000V AC
Short circuit 40kA - 150kA / 1Sec
System 3 Pole or 4 Pole
Earthning 50% integral or internal Earth
IP IP40 - IP66
Standards UL 857 / IEC61439-6: 2012
Plug in units 16A - 1600A with Schneider Electric Breakers
인증
Complete Certification Simple Certification
Full type test(25 verifications) Any test specified by Manufacturer
Product and product line One sample
Continuous surveillance One time test
Safety Mark, Quality assurance Conformity is not guaranteed
Latest standard Any standard specified
Track power busduct
Fast sliding installationwith fool-proof design 1 Easy installationwithout risk ofinterference 2 Option: Metering of linesand tap-off units 5 Compact size tap-off unitdesign to ensure the highdensity 6 Daisy-chain design withModbus communication 7 Elastic Spring Jaw 3 Hot plug design &Fast deployment 4
1 Fast sliding installation with fool-proof design
  • Double-head bolt design with torque indicator
  • Fool-proof connection -installation cannotcontinue in case of
    wrong operation
  • Both sides contact on conductor to ensure low temperature rise
2 Easy installation without risk of interference
  • Positioning by sliding along the length
  • No interference with tap-off units
  • For threaded rods or C profile
3 Elastic Spring Jaw
  • Innovative patented design-Elastic spring jaw
  • Silver plated to ensure low contact resistance
4 Hot plug design & Fast deployment
  • Fast installation -3 seconds plug and play
  • Green visible indicator
  • Both Red Dot and lF Awards for easy lock design
5 Option: Metering of lines and tap-off units
  • Fault alarm
  • Power management
6 Compact size tap-off unit design to ensure the high density
  • Compact Tap-off unit design (minimum length 240mm)
  • Up to 6 tap-off per 3-meter straight length
  • Up to 128A
  • IP20/IP42
  • IP54(Optional)
7 Daisy-chain design with Modbus communication
  • Modbus communication
  • Daisy chain
  • Cable storage slot
주요 사양
Rated current A 250 400 630
Rated operating voltage V 1000 1000 1000
Rated insulation voltage V 1000 1000 1000
Operating frequency Hz 50 50 50
IP rating - IP42/20
Allowable rated short-time withstand current (t=1s) kA 10 17 31
Allowable rated peak current kA 28 49 65.1
Conductor characteristics
Average resistance at ambient temperature of 20° mΩ/m 0.267 0.173 0.106
Average resistance at Inc mΩ/m 0.314 0.218 0.131
Average reactance at Inc and at 50Hz mΩ/m 0.082 0.075 0.043
Average impedance at Inc and at 50Hz mΩ/m 0.325 0.231 0.138
Voltage drop at ambient temperature of 40°C, full load, load distribution factor 1
Power factor 1 V/m 0.136 0.151 0.145
0.95 V/m 0.140 0.160 0.153
0.9 V/m 0.138 0.159 0.152
0.85 V/m 0.134 0.156 0.149
0.8 V/m 0.130 0.152 0.145
Medium Power Busduct
Canalis KT
Busbar trunking for high power distribution up to 5000A
  • Rating: from 800 to 5000A
  • IP: 55
  • Plug in units max. rating : 1250A
  • Applications: Power distribution for industrial processes, link between transformer and switchboard, and transport. Raising main for transport and power distribution.
  • Market: Industry, Building, Data centres, Airports, ...
Canalis KT
Busbar trunking for medium power distribution up to 1000A
  • Rating: from 100 to 1000A
  • IP: 55
  • Tap-off intervals: 1.0 metre on each face
  • Standard lengths(m): 3, 5(defined by the floor pitch for rising main)
  • Plug in units max. rating : 400A.
  • Applications: Power socket distribution until 4 tap-off units / metre. Raising main distribution
  • Market: Marine, Building, Workshops, Industry, car parks, data centres…
Canalis KN
Busbar trunking for low power distribution up to 160A
  • Rating: 40A to 160A
  • IP: 55
  • Tap-off intervals(m): 0.5, 1.0, 3.0
  • Standard lengths(m): 3
  • Plug in units max. rating : 63A
  • Applications: protected power sockets(only with modular circuit-breakers)
  • Market: Building(Laboratories, Super / Hypermarkets, warehouses, exhibition rooms, workshops…)
Canalis KB
Busbar trunking for low lighting distribution
  • Rating: 25A, 40A single or double circuit
  • IP: 55Tap-off intervals(m): 0.5, 1.0
  • Standard lengths(m): 2, 3
  • Maximum distance between fixing points: 5 m
  • Applications: Lighting, communication bus and power socket distribution
  • Market: Building(Super / Hypermarkets, warehouses, exhibition rooms, car parks…)
Busduct System의 장점
  • 대용량 배선에서도 직각으로 간선을 설치할 수 있어 Space를 절약하는 콤팩트한 시설이 가능
  • 분기점의 구성이 간단하고 간선 계통의 간소화 가능
  • 방재성이 뛰어나고 단락 강도가 큼
  • 부하의 증감에 대한 Flexcibility가 있다.(전류 불평형, 허용전류 등)
  • 공장 가공으로 시공이 간단하고 공기단축, 공사비 절감, 신뢰성, 착오 방지 등의 장점
  • 대용량 제품의 제작이 용이
Schneider Busduct
  • 초고층 빌딩 시공 실적 전 세계적으로 초고층 빌딩 70% 이상의 시공실적을 가진 제품으로 내진(UBC ZONE4 인증)과 건물의 수축, 팽창으로 인해 발생되는 문제점 등을 보완 사용으로 검증된 제품
  • 우수한 전기적 특징 AL Busbar에 모든 접속부를 Copper Contact하여 구리와 같은 도전율이 높은 제품
  • 접지 연속성 Bolt 체결이 없는 연속 접지 시스템을 사용하여 안전성을 극대화한 제품
  • Plug In Unit(PIU) PIU와 도체가 연결되는 부분의 접촉면을 Spring 구조로 하여 시간이 흘러도 접촉 장력을 유지할 수 있는 제품
  • 친환경 인증과 안전 인증 친환경 인증 마크를 득하였고 안전 인증인 Kema Keur와 ASTA-Diamond를 취득한 제품
  • 기계적 성능 향상 AL 외함에 FE(철)을 보강하여 입상 수직 구간에서 비틀림과 휨 현상을 방지한 기계적 강도 IK10(IEC 기준) 등급 인증 제품
Solution - Copper Contact (bi-metal)
  • 모든 접속 부위(Joint KIT, Plug in)는 알루미늄 도체 표면에 은도금 된 바이메탈 판(구리와 알루미늄이 분자 결합)을 부착 하였음
  • 부착된 Copper contact은 접촉 면의 바깥쪽은 은도금된 구리이며, 안쪽은 알루미늄으로 도체 부착 시 이종 금속의 문제점을 해소 함
  • 모든 Busduct의 접촉면은 은과 은이 접촉 됨. Copper contact은 접촉저항이 가변 하는 부분에만 적용됨(Joint, Plug in)
지진 법령 준수
  • 전 생산 품목에 걸쳐서 보다 가혹한 조건인 UBC zone 4로 시험하고 인증을 받음
  • 지진 전문 연구기관인 EERTC (Earthquake Engineering Research & Test Centre)에서 시험하고,
    전세계적으로 지진 피해가 가장 심각한 일본의 지진전문가(Shimizu Corporation Japan)가 시험 과정을 참관 하였음
  • 기계적 강도(휨현상, 뒤틀림현상)시험와 1940년의 미국의 El centro와 1995년의 일본 고베, 2004년의 오지야의 지진 재현 시험을 하여 무사히 통과 하였음
설치 예